448 Yingchun Road, Wangchun Industrial Park, Ningbo 315175, Zhejiang, China
+86 574 87155635
+86 574 87153117
(# 8108 or 8817)
+86 13957414697
+86 574 87155951
sentek01
+86 13957414697
nbsentek
Availability: | |
---|---|
SD119-2
Sentek
Conventional Photoelectric Smoke and Heat Alarm
All of the Sentek’s SD119 series detectors meet the requirements of UL 268 and EN 54-7/5 for use in fire alarm signaling systems. They are intended for use in 2-wire/4-wire Class A or B supervised zone circuits. The SD119 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.
The SD119 series include 2-wire and 4-wire detectors, which provide fast and reliable response for
photoelectric smoke and heat (135°F ) detection. While the smoke and heat detection circuits operate independently, their outputs being "OR' connected, The Sentek’s SD119 series detectors provide the fire detection performance by acting as a smoke sensor and/or a 135°F heat detector at the same location.
• 2 or 4 wire models
• Advanced detection and discrimination algorithms
• Easy installation and maintenance
• Sleek low-profile housing design
• Durable sensor head, no need for replacement
• SMD circuit board design-satisfactory quality and reliability guaranteed
• Integrated heat detector for SD119-2H and SD119-4H models
• N/C (normal/close)-N/O (normal/open)selectable relay output
• AR (Auto Reset) function for security systems (optional for 4 wire models) Sensor base option:
standard and Shottky Diode
• Five-year limited warranty
SD119- 2 | 2 wire photoelectric smoke alarm |
SD119- 2- LED | 2 wire photoelectric smoke alarm with remote LED output |
SD119- 2H | 2 wire photoelectric smoke and heat alarm |
SD119- 2H- LED | 2 wire photoelectric smoke and heat alarm with remote LED output |
SD119- 4 | 4 wire heat alarm with auto-reset function (12/24VDC) |
SD119- 4B | 4 wire photoelectric smoke alarm with Buzzer (12/24/48VDC) |
SD119- 4AR | 4 wire photoelectric smoke alarm with auto-reset function (12/24/48VDC) |
SD119- 4ARB | 4 wire photoelectric smoke alarm with auto-reset function and Buzzer (12/24/48VDC) |
SD119- 4H | 4 wire photoelectric smoke and heat alarm (12/24/48VDC) |
SD119- 4HB | 4 wire photoelectric smoke and heat alarm with Buzzer (12/24/48VDC) |
SD119- 4HAR | 4 wire photoelectric smoke and heat alarm with auto-reset function (12/24/48VDC) |
Model | 2/4 wire | Thermal | Voltage DC | Standby Current (Max.) | Alarm Current 12/24V | Surge Current (Max.) | Star-Up Time (Max.) | Permissible Current (Max.) | Frequency | Alarm contact | Base model |
SD119-2 | 2 | 10.8〜33V | 80μA | 22/55mA | 160μA | 30S | 80mA | 1〜3 Seconds | — | P/N852001 | |
SD119-2L | 2 | 10.8〜33V | 80μA | 22/55mA | 160μA | 30S | 80mA | 1〜3 Seconds | — | P/N854001 | |
SD119-2H | 2 | 57°C | 10.8〜33V | 80μA | 22/55mA | 160μA | 30S | 80mA | 1〜3 Seconds | — | P/N852001 |
SD119-2HL | 2 | 57°C | 10.8〜33V | 80μA | 22/55mA | 160μA | 30S | 80mA | 1〜3 Seconds | — | P/N854001 |
SD119-4-12V | 4 | 10.8〜33V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
SD119-4-24V | 4 | 20~27.6V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
S119-4H-12V | 4 | 57°C | 10~13.8V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
S119-4H-24V | 4 | 57°C | 20~27.6V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4AR-12V | 4 | 10~13.8V | 100μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 | |
SD119-4AR-24V | 4 | 20~27.6V | 100μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 | |
SD119-4HAR-12V | 4 | 57°C | 10~13.8V | 100μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
SD119-4HAR-24V | 4 | 57°C | 20~27.6V | 100μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4B-12V | 4 | 10~13.8V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
SD119-4B-24V | 4 | 20~27.6V | 80μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
SD119-4HB-12V | 4 | 57°C | 10~13.8V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4HB-24V | 4 | 57°C | 20~27.6V | 80μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4HARB-12V | 4 | 57°C | 10~13.8V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
SD119-4HARB-24V | 4 | 57°C | 20~27.6V | 80μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
SD119-4-48V | 4 | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
SD119-4AR-48V | 4 | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 | |
SD119-4H-48V | 4 | 57°C | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4HAR-48V | 4 | 57°C | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
SD119-4HARB48V | 4 | 57°C | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
Smoke Sensitivity | 0.08~0.2db/m(EN standard) or 0.98~4.0%/FT Obscuration (UL standard) |
Ceiling Spacing | 50 foot rating for heat sensor |
Reset Voltage | less than 1 volt |
Reset Time | less than 1 second |
Alarm Indicator | LED continuously emitting red light |
Remote Output | 25 mA max., diode gate |
Temperature Range | -10°C to 55°C, UL268 temperature: 0~37.8°C |
Permissible Current | 80mA maximum |
Humidity | 0 to 95% RH, no condensation or icing |
Alarm Contact | (for 4-wire) NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC |
Dimensions | 100mm (dia) x 46mm (ht) with base |
Weight | 130g/set with base |
Conventional Photoelectric Smoke and Heat Alarm
All of the Sentek’s SD119 series detectors meet the requirements of UL 268 and EN 54-7/5 for use in fire alarm signaling systems. They are intended for use in 2-wire/4-wire Class A or B supervised zone circuits. The SD119 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.
The SD119 series include 2-wire and 4-wire detectors, which provide fast and reliable response for
photoelectric smoke and heat (135°F ) detection. While the smoke and heat detection circuits operate independently, their outputs being "OR' connected, The Sentek’s SD119 series detectors provide the fire detection performance by acting as a smoke sensor and/or a 135°F heat detector at the same location.
• 2 or 4 wire models
• Advanced detection and discrimination algorithms
• Easy installation and maintenance
• Sleek low-profile housing design
• Durable sensor head, no need for replacement
• SMD circuit board design-satisfactory quality and reliability guaranteed
• Integrated heat detector for SD119-2H and SD119-4H models
• N/C (normal/close)-N/O (normal/open)selectable relay output
• AR (Auto Reset) function for security systems (optional for 4 wire models) Sensor base option:
standard and Shottky Diode
• Five-year limited warranty
SD119- 2 | 2 wire photoelectric smoke alarm |
SD119- 2- LED | 2 wire photoelectric smoke alarm with remote LED output |
SD119- 2H | 2 wire photoelectric smoke and heat alarm |
SD119- 2H- LED | 2 wire photoelectric smoke and heat alarm with remote LED output |
SD119- 4 | 4 wire heat alarm with auto-reset function (12/24VDC) |
SD119- 4B | 4 wire photoelectric smoke alarm with Buzzer (12/24/48VDC) |
SD119- 4AR | 4 wire photoelectric smoke alarm with auto-reset function (12/24/48VDC) |
SD119- 4ARB | 4 wire photoelectric smoke alarm with auto-reset function and Buzzer (12/24/48VDC) |
SD119- 4H | 4 wire photoelectric smoke and heat alarm (12/24/48VDC) |
SD119- 4HB | 4 wire photoelectric smoke and heat alarm with Buzzer (12/24/48VDC) |
SD119- 4HAR | 4 wire photoelectric smoke and heat alarm with auto-reset function (12/24/48VDC) |
Model | 2/4 wire | Thermal | Voltage DC | Standby Current (Max.) | Alarm Current 12/24V | Surge Current (Max.) | Star-Up Time (Max.) | Permissible Current (Max.) | Frequency | Alarm contact | Base model |
SD119-2 | 2 | 10.8〜33V | 80μA | 22/55mA | 160μA | 30S | 80mA | 1〜3 Seconds | — | P/N852001 | |
SD119-2L | 2 | 10.8〜33V | 80μA | 22/55mA | 160μA | 30S | 80mA | 1〜3 Seconds | — | P/N854001 | |
SD119-2H | 2 | 57°C | 10.8〜33V | 80μA | 22/55mA | 160μA | 30S | 80mA | 1〜3 Seconds | — | P/N852001 |
SD119-2HL | 2 | 57°C | 10.8〜33V | 80μA | 22/55mA | 160μA | 30S | 80mA | 1〜3 Seconds | — | P/N854001 |
SD119-4-12V | 4 | 10.8〜33V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
SD119-4-24V | 4 | 20~27.6V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
S119-4H-12V | 4 | 57°C | 10~13.8V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
S119-4H-24V | 4 | 57°C | 20~27.6V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4AR-12V | 4 | 10~13.8V | 100μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 | |
SD119-4AR-24V | 4 | 20~27.6V | 100μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 | |
SD119-4HAR-12V | 4 | 57°C | 10~13.8V | 100μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
SD119-4HAR-24V | 4 | 57°C | 20~27.6V | 100μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4B-12V | 4 | 10~13.8V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
SD119-4B-24V | 4 | 20~27.6V | 80μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
SD119-4HB-12V | 4 | 57°C | 10~13.8V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4HB-24V | 4 | 57°C | 20~27.6V | 80μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4HARB-12V | 4 | 57°C | 10~13.8V | 80μA | 30mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
SD119-4HARB-24V | 4 | 57°C | 20~27.6V | 80μA | 45mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
SD119-4-48V | 4 | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 | |
SD119-4AR-48V | 4 | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 | |
SD119-4H-48V | 4 | 57°C | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A | P/N854001 |
SD119-4HAR-48V | 4 | 57°C | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
SD119-4HARB48V | 4 | 57°C | 10.8~60V | 80μA | 25mA | 160μA | 30S | 80mA | 1〜3 Seconds | Form A /Auto Reset | P/N854001 |
Smoke Sensitivity | 0.08~0.2db/m(EN standard) or 0.98~4.0%/FT Obscuration (UL standard) |
Ceiling Spacing | 50 foot rating for heat sensor |
Reset Voltage | less than 1 volt |
Reset Time | less than 1 second |
Alarm Indicator | LED continuously emitting red light |
Remote Output | 25 mA max., diode gate |
Temperature Range | -10°C to 55°C, UL268 temperature: 0~37.8°C |
Permissible Current | 80mA maximum |
Humidity | 0 to 95% RH, no condensation or icing |
Alarm Contact | (for 4-wire) NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC |
Dimensions | 100mm (dia) x 46mm (ht) with base |
Weight | 130g/set with base |
+86 574 87155635, 87153117
# 8108 or 8817
+86 180-5855-7012
sales@sentek.cc , service@sentek.cc
sentek01
Copyright © 2020 Ningbo SENTEK Electronics CO., LTD