SENTEK 4 wire Conventional Smoke Detector for Fire Security Aystem

• 2 or 4 wire models
• Advanced detection and discrimination algorithms
• Easy installation and maintenance
• Sleek low-profile housing design
• Durable sensor head, no need for replacement
• SMD circuit board design-satisfactory quality and reliability guaranteed
• Integrated heat detector for SD119-2H and SD119-4H models
• N/C (normal/close)-N/O (normal/open)selectable relay output
• AR (Auto Reset) function for security systems (optional for 4 wire models) Sensor base option:
standard and Shottky Diode
• Five-year limited warranty
Availability:
  • SD119-2

  • Sentek


SD119 Series

Conventional Photoelectric Smoke and Heat Alarm

All of the Sentek’s SD119 series detectors meet the requirements of UL 268 and EN 54-7/5 for use in fire alarm signaling systems. They are intended for use in 2-wire/4-wire Class A or B supervised zone circuits. The SD119 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.

The SD119 series include 2-wire and 4-wire detectors, which provide fast and reliable response for

photoelectric smoke and heat (135°F ) detection. While the smoke and heat detection circuits operate independently, their outputs being "OR' connected, The Sentek’s SD119 series detectors provide the fire detection performance by acting as a smoke sensor and/or a 135°F heat detector at the same location.

Product Features

•  2 or 4 wire models 

•  Advanced detection and discrimination algorithms 

•  Easy installation and maintenance 

•  Sleek low-profile housing design 

•  Durable sensor head, no need for replacement 

•  SMD circuit board design-satisfactory quality and reliability guaranteed 

•  Integrated heat detector for SD119-2H and SD119-4H models 

•  N/C (normal/close)-N/O (normal/open)selectable relay output

•  AR (Auto Reset) function for security systems (optional for 4 wire models) Sensor base option:

standard and Shottky Diode

•  Five-year limited warranty

The range includes


SD119- 2  

2 wire photoelectric smoke alarm

SD119- 2- LED

2 wire photoelectric smoke alarm with remote LED output

SD119- 2H  

2 wire photoelectric smoke and heat alarm

SD119- 2H- LED 

2 wire photoelectric smoke and heat alarm with remote LED output

SD119- 4

4 wire heat alarm with auto-reset function (12/24VDC)

SD119- 4B

4 wire photoelectric smoke alarm with Buzzer (12/24/48VDC)

SD119- 4AR

4 wire photoelectric smoke alarm with auto-reset function (12/24/48VDC)

SD119- 4ARB 

4 wire photoelectric smoke alarm with auto-reset function and Buzzer (12/24/48VDC)

SD119- 4H

4 wire photoelectric smoke and heat alarm (12/24/48VDC)

SD119- 4HB 

4 wire photoelectric smoke and heat alarm with Buzzer (12/24/48VDC)
SD119- 4HAR 4 wire photoelectric smoke and heat alarm with auto-reset function (12/24/48VDC)


Product  Specification


Model  

2/4 wire

Thermal

Voltage DC

Standby

Current

(Max.)

Alarm

Current

12/24V


Surge

Current

(Max.)

Star-Up

Time

(Max.)

Permissible

Current

(Max.)

Frequency  Alarm contact Base model

SD119-2 

2


10.8〜33V  80μA  22/55mA    160μA    30S 80mA   1〜3 Seconds    P/N852001

SD119-2L   

2


10.8〜33V  80μA 22/55mA     160μA    30S 80mA   1〜3 Seconds  P/N854001

SD119-2H 

2  

57°C  10.8〜33V  80μA 22/55mA     160μA     30S 80mA    1〜3 Seconds  P/N852001

SD119-2HL

2

57°C  10.8〜33V 80μA 22/55mA    160μA    30S 80mA   1〜3 Seconds      P/N854001

SD119-4-12V    

4


10.8〜33V 80μA  30mA     160μA    30S 80mA   1〜3 Seconds    Form A   P/N854001

SD119-4-24V     

4


20~27.6V   80μA  30mA    160μA   30S 80mA   1〜3 Seconds   Form A   P/N854001

     S119-4H-12V  

4

57°C 10~13.8V  80μA 30mA     160μA   30S 80mA    1〜3 Seconds  Form A   P/N854001

   S119-4H-24V    

4

57°C 20~27.6V 80μA 30mA     160μA   30S 80mA    1〜3 Seconds  Form A   P/N854001

     SD119-4AR-12V  

4


10~13.8V  100μA  30mA   160μA    30S 80mA    1〜3 Seconds  Form A /Auto Reset   P/N854001

     SD119-4AR-24V 

4


20~27.6V 100μA  45mA    160μA   30S 80mA    1〜3 Seconds  Form A /Auto Reset  P/N854001

    SD119-4HAR-12V 

4

57°C 10~13.8V 100μA 30mA     160μA   30S 80mA    1〜3 Seconds  Form A /Auto Reset  P/N854001

    SD119-4HAR-24V  

4

57°C 20~27.6V 100μA  45mA   160μA    30S   80mA  1〜3 Seconds  Form A  P/N854001

     SD119-4B-12V  

4


10~13.8V  80μA  30mA    160μA   30S   80mA  1〜3 Seconds  Form A  P/N854001

 SD119-4B-24V  

4


20~27.6V  80μA  45mA  160μA    30S   80mA  1〜3 Seconds  Form A  P/N854001

 SD119-4HB-12V       

4

57°C 10~13.8V 80μA  30mA  160μA   30S   80mA 1〜3 Seconds   Form A  P/N854001

  SD119-4HB-24V       

4

57°C 20~27.6V 80μA  45mA    160μA   30S   80mA  1〜3 Seconds  Form A  P/N854001

  SD119-4HARB-12V  

4

57°C 10~13.8V  80μA 30mA    160μA    30S   80mA  1〜3 Seconds  Form A /Auto Reset   P/N854001

SD119-4HARB-24V     

4

57°C 20~27.6V 80μA  45mA   160μA    30S   80mA  1〜3 Seconds  Form A /Auto Reset   P/N854001

     SD119-4-48V  

4


10.8~60V 80μA 25mA    160μA   30S   80mA  1〜3 Seconds  Form A  P/N854001

     SD119-4AR-48V

4


10.8~60V 80μA 25mA    160μA   30S   80mA  1〜3 Seconds  Form A /Auto Reset P/N854001

  SD119-4H-48V     

4

57°C  10.8~60V 80μA 25mA   160μA    30S   80mA  1〜3 Seconds  Form A   P/N854001

   SD119-4HAR-48V   

4

57°C  10.8~60V 80μA 25mA   160μA    30S   80mA  1〜3 Seconds Form A /Auto Reset  P/N854001

 SD119-4HARB48V    

4

57°C   10.8~60V 80μA 25mA   160μA    30S    80mA  1〜3 Seconds Form A /Auto Reset  P/N854001


Product Character


Smoke Sensitivity

0.08~0.2db/m(EN standard) or 0.98~4.0%/FT Obscuration (UL standard)

Ceiling Spacing

50 foot rating for heat sensor

Reset Voltage

less than 1 volt

Reset Time

less than 1 second

Alarm Indicator

LED continuously emitting red light

Remote Output

25 mA max., diode gate

Temperature Range

-10°C to 55°C, UL268 temperature: 0~37.8°C

Permissible Current

80mA maximum

Humidity

0 to 95% RH, no condensation or icing

Alarm Contact

(for 4-wire) NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC

Dimensions

100mm (dia) x 46mm (ht) with base

Weight

130g/set with base



Certificate