448 Yingchun Road, Wangchun Industrial Park, Ningbo 315175, Zhejiang, China
+86 574 87155635
+86 574 87153117
(# 8108 or 8817)
+86 13957414697
+86 574 87155951
sentek01
+86 13957414697
nbsentek
Availability: | |
---|---|
AM-111
Sentek
Addressable Module AM111 allows the connection and addressing of Conventional Detectors, Call Points, Input, Output and Conventional
Sounder/ Beacon.
With its small physical size and convenient 8 way DIL switch for address setting and configuration, the AM111 provides the facility to upgrade all the components of a conventional system to a full addressable system, making it an ideal solution for retrofitting installations. The AM111 is fully compatible with all standard addressable modules, addressable sounders, addressable manual call points facilitating extensions to
existing systems.
Device type selection is by means of switch 8 on the DIL. In Sounder mode the output is removed when a Silence Alarm signal is received from the control panel. In Output mode the output remains active until the system is reset.
Model | DESCRIPTION |
AM111-D | Addressed Module for SMOKE or HEAT Detector (WHITE) |
AM111-C | Addressed Module for CALL POINT or INPUT (RED) |
AM111-S | Addressed Module for Micro Output Module/ Loop Sounder (YELLOW) |
Supply Voltage | Loop Powered 17 – 30 V |
Quiescent Current | 300uA @ 17 – 30 V Loop Powered AM111-C AM111-D |
700uA @ 17 – 30 V Loop Powered AM111-S | |
Alarm Current | 13mA AM111-C AM111-D |
1.1 mA AM111-S(No attachment devices) | |
Reset Time | 20 seconds |
Address Range | 1-125 |
Temperature /Relative Humidity | -10°C to 55°C / 0 to 95% RH, no condensation or icing |
Dimensions / Weight | 49 (L) x 25 (W) x 13 (H) mm / 18g |
Addressable Module AM111 allows the connection and addressing of Conventional Detectors, Call Points, Input, Output and Conventional
Sounder/ Beacon.
With its small physical size and convenient 8 way DIL switch for address setting and configuration, the AM111 provides the facility to upgrade all the components of a conventional system to a full addressable system, making it an ideal solution for retrofitting installations. The AM111 is fully compatible with all standard addressable modules, addressable sounders, addressable manual call points facilitating extensions to
existing systems.
Device type selection is by means of switch 8 on the DIL. In Sounder mode the output is removed when a Silence Alarm signal is received from the control panel. In Output mode the output remains active until the system is reset.
Model | DESCRIPTION |
AM111-D | Addressed Module for SMOKE or HEAT Detector (WHITE) |
AM111-C | Addressed Module for CALL POINT or INPUT (RED) |
AM111-S | Addressed Module for Micro Output Module/ Loop Sounder (YELLOW) |
Supply Voltage | Loop Powered 17 – 30 V |
Quiescent Current | 300uA @ 17 – 30 V Loop Powered AM111-C AM111-D |
700uA @ 17 – 30 V Loop Powered AM111-S | |
Alarm Current | 13mA AM111-C AM111-D |
1.1 mA AM111-S(No attachment devices) | |
Reset Time | 20 seconds |
Address Range | 1-125 |
Temperature /Relative Humidity | -10°C to 55°C / 0 to 95% RH, no condensation or icing |
Dimensions / Weight | 49 (L) x 25 (W) x 13 (H) mm / 18g |